ANL-A Automotive Fuse (Bolt Fuse)
- Dimensions (mm)
2.Specifications
Housing: Out of thermoplastic (UL 94-V0, heat-resistant) Visible melting element
Terminal: Copper alloy, gal. Sn 2 x M8 bolts, Distance 60 mm
Mounting Torque: 12.0 Nm +/- 1Nm
Breaking Capacity: 12V24V32V48V58V DC
Implementation criteria: DIN 43560/1
3.Time-Current Characteristics
% of Rating |
Opening Time Min / Max (s) |
|
30A - 200A |
225A-500A |
|
|
|
|
150 |
3600S |
--- |
160 |
|
60S |
220 |
1 s / 60 s |
1 s / 60s |
250 |
0.800 s / 10s |
0.800 s / 10 s |
400 |
0.200 s / 2s |
0.200 s / 2 s |
4.Ratings
TYPE |
Rating Current(A) |
Typ Voltage drop |
ANL-A030 |
30A |
≤150Mv |
ANL-A040 |
40A |
≤150Mv |
ANL-A050 |
50A |
≤150Mv |
ANL-A060 |
60A |
≤130mV |
ANL-A080 |
80A |
≤130mV |
ANL-A100 |
100A |
≤110mV |
ANL-A125 |
125A |
≤110mV |
ANL-A150 |
150A |
≤100mV |
ANL-A175 |
175A |
≤100mV |
ANL-A200 |
200A |
≤100mV |
ANL-A250 |
250A |
≤90mV |
ANL-A300 |
300A |
≤90mV |
ANL-A350 |
350A |
≤90mV |
ANL-A400 |
400A |
≤90mV |
ANL-A500 |
500A |
≤90mV |
ANL-A600 |
600A |
≤90mV |