Top

1H20L (70A-300A) aR fast fuse/new energy fuse

1H20L (70A-300A) aR fast fuse/new energy fuse

1H20L (70A-300A) aR fast fuse/new energy fuse

1H20L (70A-300A) aR fast fuse/new energy fuse

Description

1H20L (70A-300A) aR fast fuse/new energy fuse

                  1H20L Series DC(EV) fuse

1Purpose and use

 This series of fuses are suitable for lines with rated DC voltage below 250V (125V), rated current of 70A-300A and breaking capacity of 20kA. They are widely used in semiconductor protection, mobile forklift, electric elevator, charger, power supply, on-board battery, on-board circuit system and inverter integrated protection. At the same time, it has the characteristics of strong current limiting capacity, large breaking capacity and fast short-circuit breaking speed. Can withstand temperature shock, mechanical shock, current shock, chemical load, etc.Performance refers to JASOD622, and environmental reliability conforms to ISO8820, JASOD622 and GB / T31465 

2Normal working conditions

Normal operating conditions of ambient air temperature: - 5 ℃ ~ 40 ℃; allowable operating conditions: - 40 ℃ ~ + 125 ℃;

3. Use category

Full range fast fuse(gR)

4. Structural characteristics

The melting tube of the product is made of high-temperature resistant ceramic material, with high flame-retardant performance and strong hardness.

The melt is sealed in the melting tube with a variable cross-section melt made of 99.99% pure silver. The melting tube is filled with chemically treated high-purity quartz sand and specially treated chemical materials as arc extinguishing medium. The contact surface is silver plated to ensure reliable electrical performance, greatly reducing temperature rise and power consumption; Both ends of the melt are firmly connected with the contact by spot welding, which greatly enhances the safety and reliability of breaking short circuit fault current

5. Agreed current and agreed time

Test current

A

Fusing time s

In:≥60A

min

max

1.1In

14400

-

1.35In

150

3600

1.5In

20

1500

2In

1

300

3In

0.2

30

5In

0.05

1

 

Note: the agreed current and agreed time required by the customer can be negotiated with our company.

The characteristics of fuse will vary according to the use environment and surrounding design requirements. The performance characteristics are obtained according to the rated constant temperature of 25 ℃

 

6. Main parameters

NO:

Product model

Rated current

A

 

Breaking Capacity

KA

Rated  voltage

DC (V)

Maximum voltage drop

110%(mV)

1

1H20L070

70

125V/150V

100

20

2

1H20L080

80

125V/150V

90

20

3

1H20L100

100

125V/150V

96

20

4

1H20L125

125

125V/150V

86

20

5

1H20L150

150

125V/150V

96

20

6

1H20L200

200

125V/150V

87

20

7

1H20L250

250

125V/150V

84

20

8

1H20L300

300

125V/150V

85

20