1.Purpose and use
This series of fuses are suitable for lines with rated DC voltage below 250V (125V), rated current of 70A-300A and breaking capacity of 20kA. They are widely used in semiconductor protection, mobile forklift, electric elevator, charger, power supply, on-board battery, on-board circuit system and inverter integrated protection. At the same time, it has the characteristics of strong current limiting capacity, large breaking capacity and fast short-circuit breaking speed. Can withstand temperature shock, mechanical shock, current shock, chemical load, etc.Performance refers to JASOD622, and environmental reliability conforms to ISO8820, JASOD622 and GB / T31465
2.Normal working conditions
Normal operating conditions of ambient air temperature: - 5 ℃ ~ 40 ℃; allowable operating conditions: - 40 ℃ ~ + 125 ℃;
3. Use category
Full range fast fuse(gR)
4. Structural characteristics
The melting tube of the product is made of high-temperature resistant ceramic material, with high flame-retardant performance and strong hardness.
The melt is sealed in the melting tube with a variable cross-section melt made of 99.99% pure silver. The melting tube is filled with chemically treated high-purity quartz sand and specially treated chemical materials as arc extinguishing medium. The contact surface is silver plated to ensure reliable electrical performance, greatly reducing temperature rise and power consumption; Both ends of the melt are firmly connected with the contact by spot welding, which greatly enhances the safety and reliability of breaking short circuit fault current
5. Agreed current and agreed time
Test current A |
Fusing time s |
|
In:≥60A |
||
min |
max |
|
1.1In |
14400 |
- |
1.35In |
150 |
3600 |
1.5In |
20 |
1500 |
2In |
1 |
300 |
3In |
0.2 |
30 |
5In |
0.05 |
1 |
Note: the agreed current and agreed time required by the customer can be negotiated with our company.
The characteristics of fuse will vary according to the use environment and surrounding design requirements. The performance characteristics are obtained according to the rated constant temperature of 25 ℃
6. Main parameters
NO: |
Product model |
Rated current (A) |
|
Breaking Capacity (KA) |
|
Rated voltage DC (V) |
Maximum voltage drop 110%(mV) |
||||
1 |
1H20L070 |
70 |
125V/150V |
100 |
20 |
2 |
1H20L080 |
80 |
125V/150V |
90 |
20 |
3 |
1H20L100 |
100 |
125V/150V |
96 |
20 |
4 |
1H20L125 |
125 |
125V/150V |
86 |
20 |
5 |
1H20L150 |
150 |
125V/150V |
96 |
20 |
6 |
1H20L200 |
200 |
125V/150V |
87 |
20 |
7 |
1H20L250 |
250 |
125V/150V |
84 |
20 |
8 |
1H20L300 |
300 |
125V/150V |
85 |
20 |