Top

GFEPVT1500-74ES Photovoltaic Fuse 100A-800A 1500V dc

GFEPVT1500-74ES Photovoltaic Fuse 100A-800A 1500V dc

GFEPVT1500-74ES Photovoltaic Fuse 100A-800A 1500V dc

Lorem ipsum dolor sit amet, consectetur adipisicing elit. Libero velit id eaque ex quae laboriosam nulla optio doloribus! Perspiciatis, libero, neque, perferendis at nisi optio dolor!
Description
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Libero velit id eaque ex quae laboriosam nulla optio doloribus! Perspiciatis, libero, neque, perferendis at nisi optio dolor!

Dimensions (mm)


Bolted xxB-74ES Dimensions

Din xxxU-74ES Dimensions

Description

  • Low I²t value
  • Strong current limiting capability
  • Low voltage drop
  • Excellent DC performance
  • Capable of interrupting low overcurrents associated with faulted PV strings

Standards & Approvals

  • Refer to UL-248-19 / IEC 60269-1/6
  • Reach declaration available upon request
  • RoHS compliant

Features & Benefits

  • The GFEPVT1500 series is designed to meet the emerging circuit protection needs for 1500-volt photovoltaic systems
  • Provides full range protection for all potential overcurrent conditions in PV applications
  • Suitable for PV inverter protection and array combiner applications

Product Characteristics

Item Test Condition/Methods Standard Performance
Time/Current 100% of current rating UL248-19 No Fusing;4 hours Min.
105% of current rating *UL UL-248.19 60 Minutes Min.
135% of current rating *UL UL-248.19; (61-600A) 120 Minutes Max.
150% of current rating *UL UL-248.19;(601-800A) 240 Minutes Max.
200% of current rating UL248-19;(61-100A) 8 Minutes Max.
UL248-19;(101-200A) 10 Minutes Max.
UL248-19;(201-400A) 12 Minutes Max.
UL248-19;(401-600A) 14 Minutes Max.
Endurance Test 100% of rating current for 4 hours and testing Temperature rise at the last 5min. UL248-19 ≤65K
  • Loading 100% Rated Current (1.0In A) for flowing, and it’s available to let current keep on flowing at least 4 hour without any melting.

Fuse Ratings

Connect Part No. Fuse Amps Average @50KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²t Clearing 100% 70% TUV
Bolted

74ES

HCPVT1500-100B-74ES 100A 3,700 13,000 48 28 Pending
HCPVT1500-125B-74ES 125A 5,400 21,000 60 32 Pending
HCPVT1500-160B-74ES 160A 8,400 32,000 68 36 Pending
HCPVT1500-200B-74ES 200A 13,500 55,000 79 40 Pending
HCPVT1500-250B-74ES 250A 26,500 105,000 82 45 Pending
HCPVT1500-315B-74ES 315A 50,500 201,500 95 55 Pending
HCPVT1500-350B-74ES 350A 65,000 320,000 100 58 Pending
HCPVT1500-400B-74ES 400A 85,000 354,000 110 65 Pending
HCPVT1500-500B-74ES 500A 217,000 750,000 125 72 Pending
HCPVT1500-630B-74ES 630A 434,000 1,150,000 130 78 Pending
HCPVT1500-700B-74ES 700A 510,900 1,450,000 142 86 Pending
HCPVT1500-800B-74ES 800A 786,000 1,865,000 155 94 Pending

Connect Part No. Fuse Amps Average @50KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²t Clearing 100% 70% TUV
Din

74ES

GFEPVT1500-100U-74ES 100A 3,700 13,000 48 28 Pending
GFEPVT1500-125U-74ES 125A 5,400 21,000 60 32 Pending
GFEPVT1500-160U-74ES 160A 8,400 32,000 68 36 Pending
GFEPVT1500-200U-74ES 200A 13,500 55,000 79 40 Pending
GFEPVT1500-250U-74ES 250A 26,500 105,000 82 45 Pending
GFEPVT1500-315U-74ES 315A 50,500 201,500 95 55 Pending
GFEPVT1500-350U-74ES 350A 65,000 320,000 100 58 Pending
GFEPVT1500-400U-74ES 400A 85,000 354,000 110 65 Pending
GFEPVT1500-500U-74ES 500A 217,000 750,000 125 72 Pending
GFEPVT1500-630U-74ES 630A 434,000 1,150,000 130 78 Pending
GFEPVT1500-700U-74ES 700A 510,900 1,450,000 142 86 Pending
GFEPVT1500-800U-74ES 800A 786,000 1,865,000 155 94 Pending
  • DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃;